One Part, Dual Curing Adhesive UV23FLDC-80TK
UV23FLDC-80TK
One component, UV and heat curable epoxy system with moderate viscosity that cures with good flexibility
Dielectric Constant
4.7
Elongation
90-100% at 75°F
  • RoHS Compliant
  • Encapsulation
  • Bonding
  • Sealing
  • Coating
  • Gap Filling
25,000-50,000 cps initial cure utilizing UV light along with secondary curing in shadowed out areas by heating, typically 60-90 minutes at 80-85°C 45-55 Shore D -80°F to +300°F /de/tds/uv23fldc-80tk
UV25 One Part UV Curable System
UV25
One part, moderate viscosity UV curable system meets NASA low outgassing specifications
Glass Transition Temperature (Tg)
180-185°C
Refractive Index
1.55
  • NASA Low Outgassing
  • RoHS Compliant
  • 1,000 Hours at 85°C/85% RH
  • Bonding
  • Sealing
  • Coating
  • Gap Filling
7,000-11,000 cps cures readily in 20-30 seconds when exposed to a UV light source emitting at a wavelength of 320-365 nm with an energy output as low as 20-40 milliwatts per cm² 80-90 Shore D -60°F to +500°F /de/tds/uv25
UV curable adhesive with high thermal stability UV26
UV26
One part, low viscosity UV curable system featuring high temperature resistance for bonding
Glass Transition Temperature (Tg)
160 to 170°C
Refractive Index
1.55
  • NASA Low Outgassing
  • RoHS Compliant
  • Bonding
  • Sealing
250-1,500 cps UV light 320-365 nm for 10-20 seconds 80-90 Shore D -60°F to +500°F /de/tds/uv26
UV26DC
One component ester acrylate system cures with UV plus heat and provides high glass transition temperature
Glass Transition Temperature (Tg)
160-170°C
Refractive Index
1.52
  • NASA Low Outgassing
  • RoHS Compliant
  • Bonding
  • Sealing
  • Coating
  • Gap Filling
500-3,500 cps UV light at 320-365 nm with 20-40 milliwatts/cm2 of energy; heat curing at 125°C for 2-3 hours in shadowed areas 80-90 Shore D -100°F to +400°F /de/tds/uv26dc
UV26DCMed UV Adhesive
UV26DCMed
One component, dual cure system with UV and heat curing mechanisms for bonding and sealing, passes ISO 10993-5 for cytotoxicity
Dielectric Constant
3.85
Glass Transition Temperature (Tg)
160-170°C
  • ISO 10993-5 for Cytotoxicity
  • RoHS Compliant
  • Bonding
  • Sealing
Part A: 500-3,500 cps, Part B: Cures at 110-125°C for 60-90 minutes, followed by a post cure at 120-150°C for 1-2 hours 80-90 Shore D -60°F to +500°F /de/tds/uv26dcmed
Master Bond UV26SP Epoxy System
UV26SP
One part, low viscosity UV curable system featuring high temperature resistance for bonding, sealing and coating
Glass Transition Temperature (Tg)
160 to 170°C
Refractive Index
1.55
  • NASA Low Outgassing
  • RoHS Compliant
  • Bonding
  • Sealing
  • Coating
  • Gap Filling
250-1,500 cps UV light 320-365 nm for 10-20 seconds 80-90 Shore D -60°F to +500°F /de/tds/uv26sp
X18 One Component Elastomeric System
X18
One component primer/adhesive for polyolefins
Glass Transition Temperature (Tg)
25-30°C
Volume Resistivity
>10¹⁴ ohm-cm
  • RoHS Compliant
  • Bonding
  • Priming
<2,500 cps 75°F for 12-24 hours; 150°F for 1-2 hours -60°F to +200°F /tds/x18
X18Med One Component Primer/Adhesive
X18Med
One component primer/adhesive for polyolefins, passes ISO 10993-5 test
Glass Transition Temperature (Tg)
25-30°C
Volume Resistivity
>10¹⁴ ohm-cm
  • ISO 10993-5 for Cytotoxicity
  • RoHS Compliant
  • Bonding
  • Priming
<2,500 cps 30-45 minutes with full cures in 12-24 hours; if cured at 150°F the curing time will be 1-2 hours -60°F to +200°F /de/tds/x18med
X21 Elastomer Based One Component Adhesive
X21
One component primer/adhesive for polyolefins
Glass Transition Temperature (Tg)
25-30°C
Volume Resistivity
>10¹⁴ ohm-cm
  • RoHS Compliant
  • Bonding
  • Priming
<250 cps 12-24 hours at 75°F; 1-2 hours at 150°F -60°F to +200°F /tds/x21
X21Med One Component Elastomeric System
X21Med
One component primer/adhesive for polyolefins, passes ISO 10993-5 test
Glass Transition Temperature (Tg)
25-30°C
Volume Resistivity
>10¹⁴ ohm-cm
  • ISO 10993-5 for Cytotoxicity
  • RoHS Compliant
  • Bonding
  • Priming
30-250 cps 12-24 hours at 75°F, 1-2 hours at 150°F -60°F to +200°F /de/tds/x21med

Need Expert Guidance?

Our expert engineers offer one-on-one consultations to help you navigate our extensive material library and find the right solution for your application. We ensure confidentiality and quick turnaround (1-2 business days).